Release notes for Warrior Open-Cased 131002

 

All Logging

Derived line impedance available optional output from STD tool module

 

All Logging

Bug fix to correctly show CALA (Caliper Average) depth range in Merge

 

All Logging

Bug fix to correctly show ASCTEL device mode in its device setup screen

 

CH Logging

New Sondex Device Drivers (Compatible with Warrior 8)

 

 

Release notes for Warrior Open-Cased 130528

All Logging

Warn and fall back to computer time stamps if Time Synchronization detects a large discrepancy between devices and computer.

 

 

Release notes for Warrior Open-Cased 130301

All Logging

Improve accuracy of calendar outputs (TOD, LOCTIM, UTCTIM). Now recalculates correctly.

All Logging

Warn if computer clock rate is too different from time-synced devices to allow correction.

 

 

Release notes for Warrior Open-Cased 121004

All Logging

Services editor - Initialize copy service with service name.  Show controls in red that are not applicable to current panel type.  Drag and drop to change order of services.  Bug fix controls that may get copied from other services

All Logging

Tool string editor - Show model name in tree view on right side and in change drop down list.

 

 

Release notes for Warrior Open-Cased 120802

All Logging

IMG tool module bug where multi-point calibrations were showing up as 2-points was fixed.

OH Logging

RG Lith tool PE Calibration is based off of a ratio of windows.

All Logging

Reconfiguration of WA Manchester frames from ZDEN and SGR (as used by Hotwell DSGR), more error reporting

 

 

Release notes for Warrior Open-Cased 120430

CH Logging

Probe 20 arm multi-finger caliper support

All logging

Cumulative updates for Hotwell Digital SGR (downlink attenuation now functional for WAMNCH scripts, frame counts, pulsed manchester)

 

 

Release notes for Warrior Open-Cased 120404

All logging

IDOnly sensor bug fix for usr tool module

CH Logging

Fix for Kuster PL Frames issues in release 110930

CH Logging

Updated Hotwell PNN tool processing module and configuration in standard service/tool restore files

All logging

DSP communication enhanced; especially helpful under Windows 7.

CH Logging

Kuster multi-CCL frames support, enhancements for Hotwell DSGR telemetry, Spartek CAP and ILS telemetry updates

All logging

Homco Freepoint "Set Zero" will apply any offset in the zero reading to the max. scale reading to keep the calibration gain constant

All logging

XYCaliper multi-point calibration now appears correctly in Edit->Calibrations screen.

All Logging

SDS USB Device Drivers improved and made compatible with latest Warrior 8

All logging

IMG tool module only calling for FTT variable as needed, Thickness calculations available in recalc (when not originally logged) via Edit->Tool Configuration

 

 

Release notes for Warrior Open-Cased 111108

All logging

Tools using the img.dll module will make the MINAPIWALL variable available, NOMTHK, remains to be calculated from CASEOD and CASEID variables

 

 

Release notes for Warrior Open-Cased 111021

CH Logging

Caliper imaging tools downhole calibration is now optional and defaulted to OFF

CH Logging

Support for Permaworks PTS01 and Spartek (Archer) WLD added

CH Logging

Telemetry support for Spartek WLD tool, Kuster self-ID frames (PTSC)

All logging

Migration to latest Cypress device drivers for all SDS USB devices

Memory Logging

Enhanced support for Probe UniTool

All logging

Caliper Imaging tools casing thickness and remaning wall calculations are now optional, defaulted to off. Tool data has to be centralized for validity.

 

 

Release notes for Warrior Open-Cased 110722

All Logging

Multiple Power Control dialog bug fixes for new PSAUX board

All Logging

EDSP serial port communication support bug fix

All Logging

Support for Probe Telemetry downlink auto-training

CH Logging

Job Planner option that selects shooting polarity conveyed to shooting panels that can be software monitored and controlled to prohibit incorrect set up

All Logging

USR tool module sensors can be designated "optional" in such a way that at service load, if not configured, the service will proceed to load

CH Logging

Image tool module in normal caliper mode producing IDMN and IDMX based on opposing radii, and IDMN2 and IDMX2 based on double radii

All Logging

Recorder service can now have non integral rates specified for sampling (digitization) down to 2.0 micro seconds

CH Logging

XIPE caliper tool telemetry minor updates, freeze caused from fast changes to telemetry discriminators fixed

All Logging

Inclinometer tool module bug fix to correct deviation calculations with 2-axis accelerometer packages

All Logging

Prestemp bug fix, Gowell type pressure calibration files and calculations

All Logging

Genctel data recalc issue bug fix

  

Release notes for Warrior Open-Cased 110302

OH Logging

Probe Litho Version 4 support added

CH Logging

Spartek XY Caliper support added

CH Logging

Kuster PTS-CCL telemetry support (Version 3)

CH Logging

Robertson CBL telemetry bug fix, more precision (10uS) on downlink pulse widths

OH Logging

Robertson AIT down-log bug fix: the induction data is no longer missing in a down-log.

All Logging

Updates to cater to problematic time stamped data packets from the ASEP Smart Monitor

All logging

Option for LAS Writer to use date from log heading rather than log pass date stamp.

All logging

Support for the drop in replacement PSAUX board, adds service/panel configurable current and voltage limiting and control

All logging

Support for version SHF1E Shooting Panel (ability to combine negative tool and shooting voltage)

All Logging

PowerSafeDepthFt control added, when using appropriate hardware power is inhibited until deeper than the specified depth

All Logging

Add '~Other Information' section to LAS file.  Can be used for comments longer than 255 characters.  Add [Other] section to LAS.ini, and below that enter the name(s) of the heading entry that you want in the ~Other section:  [Other]  1=COMMENT, etc.

CH Logging

Logging System providing shooting panel voltage and current calibration defaults in absence of actual performed calibrations

All Logging

Caliper Motor current calibration defaults provided per panel type in absence of actual performed calibrations, realtime caliper current output added

OH Logging

Auxilliary transformer enable/disable control added for service configurations

OH Logging

Simplec services that use mono-cable (not using SIMPLEC board hardware) will inherently imply enabling the TELA board for downlinks

All Logging

Automatic support for the PSAUX board updated to include save/retrieve of TVOLT and TCURR calibrations

All Logging

Multipulse DSP scripts now have capability to specify period measurements on individual channels

All Logging

Event Log reporting of Calibration Edits

CH Logging

Master calibration for Probe Multi-Finger Caliper bug fix

 

Release notes for Warrior Open-Cased 100827

All Logging

New option for individual services to define a minimum time before tool power can be reenabled after switching off.

All Logging

Support for Kuster SRO through comm port

All Logging

Hole volume related outputs correctly follow the user's preferred units as selected in the control panel.

PittsAN service

Bugfix data garble preventing re-sync after a sync loss

OH Logging

ELOG: Fine tuning of the target voltage/power control feedback to allow better tracking and more dynamic behavior.

CH Logging

Tracer Eject using CTRL-F8 for eject hotkey

All Logging

Support Kuster tools through panel

All Logging

Inclinometer filtering sensors, not outputs

All Logging

Support for AKS telemetry through serial port

CH Logging

CFB Flow tool module option for single signed sensor type

All Logging

Gauges can show more decimal places

All logging

PRESTEMP support for Gowell Quartz gauge

All logging

Relay Control lock up issue fixed

OH Logging

Added special handling for the FED tool for TPAO (Turkey)

OH Logging

SDSTIP - Dual Laterolog DAC control configuration bug fix, ScannerCTL added

CH Logging

BHIMG: New Drawing Reference option - can use casingID/OD variables or can use borehole ID variable +/- an offset entered in the options dialog.

All logging

MW Acoustic Scanner support

All logging

Warrior Import Program, fix for filter delay

All logging

Optional unfiltered GR output additional to filtered

All logging

Add plot job option for jpeg files - draw image to scale

All logging

AddTVD - warn if current depth entry < previous.  VSDir part of Tie-On window.  3D view - Changed default orientation -> North on top.  Enhance 3d closure so background and scales stay in the 'back' as you rotate.  InitTVDCalc check for zero points.

All logging

Log Scale Inserts for correlation curves have run/pass name included..  Speed up Iplot when plotting correlation curves.

All logging

The right click window can show correlation values also.

All logging

When editing a curve, can right click in the log insert to select a curve as well as right clicking on the curve itself.

All logging

Modified import program to support USB DAT drive - see DAT Drives ReadMe.txt in Manual folder for details.

All logging

New export program to support USB DAT drive - see DAT Drives ReadMe.txt in Manual folder for details.

CH Logging

Fixed CWH tool multi-point type functionality

All logging

Probe telemetry scriptable downlink baud rates

CH Logging

MUXB version 2 telemetry dual spinner support

OH Logging

Rt depth-offsets changing with filtering interval bug fixed.

CH Logging

Flexstak downlink slider gain control (optional) added

All logging

Report Power Monitor warnings in Event Log

All logging

Allow long serial id's for PRESTEMP tool software in the Tool Editor

All logging

PRESTEMP tool module will import external calibration files when previously imported cals had no date associated with them

All logging

ASEP smart Monitor memory leak fixed - update provided by ASEP

All logging

ASCTEL support of generic float(s) channel, "IFS" designation

All logging

Probe PTX handling ratio channel types and backward compatibe to script specified time-base counter channels

CH Logging

IMG module now uses linear interpolation.  Bad arms marked with 'X" in tool monitor window.

All logging

Can import ODBC into existing database/dataset.

All logging

Added LAS export step size 0.0025 for 400 smp/m

CH Logging

Spartek telemetry using paced downlink when available

All logging

LTEN sensor selection (LTEN or LLMTEN) stored in db for recalc purposes

All logging

Gradio module, density from single pressure sensor calculation option

CH Logging

Enhaced MUXB support for CQPT

All logging

Gradio module, density from two pressure sources averaged over specified spacing

OH Logging

Temperature correction of Robertson Geologging AIT by use of a temperature coefficients' file.

 

 

Release notes for Warrior Open-Cased 090629

All logging

Option for 5 and 6 decade log plots.  Option for bold decades on logarithmic plots.

All logging

Both hole volume values and ticks are now generated as per Sondex request.

CH Logging

Support for Alphaneutronics telemetry

All logging

Fix for the standard Printrex 820 ( non DL ) printer

OH Logging

Support Precision Electrics Relay control

OH Logging

Add Precision Electrics Dual Induction to DILP types

All logging

Log format editor - Invert insert display to match log plot.

All logging

Surface and TD alarms were not working when speed was positive for logging up.

All logging

For TVD correction, check if any inputs have depth correction selected.  Prompt user if necessary.

All logging

HEXION DSGR Tool module added

All logging

Fix preview of cal report from Acqusition window

All Logging

Alpha Neutronics telemetry based compensated neutron support added

OH Logging

Database Utilities can calculate BHV using X and Y caliper.  Can calculate volumes to surface by replacing caliper with variable above where caliper is valid.

All Logging

Use -999.25 for undefined and infinite numbers.  Use -999.25 for unpacked numbers > 11 digits.

All Logging

Can load annotations from another log pass with annotation editor

CH Logging

PIP panel Turbine and Surface Pressure support

All Logging

Inclinometer Min/Max calibration option

OH Logging

ACE 4CAL with MEL support

All

Enhanced Event Logging

All

Inclinometer time to depth mode compatible

CH Logging

SCBL optional pseudo 3ft amp from sector calc

All

AuxPS device supporting HVAC control via tool power dialog or configured on/off

All

MUXB version 2 telemetry support - QP/QT channels

 

 

Release notes for Warrior Open-Cased 081212

OH Logging

Corrected handling of Dead time correction with the tool halving counts sent uphole.

OH Logging

Support for Gearhart LSS gain bits

CH Logging

Added user mnemonics to CWH tool module

All logging

Noise sound files should now play back in Windows VISTA.

All logging

Corrected sound file normalization, and correct gain value in dB.

All logging

Wavefile export dialog shows station number instead of ordinal number.

CH Logging

Support Panex 2nd PQ DSRO

CH Logging

Enhancements to log Gradio based on dual pressure outputs

OH Logging

Support for Gearhart LSS

OH Logging

RobGeo RG_LITH tool: PE curve has ability to apply gain/offset via a calibration; calibration time is 5 minutes.

CH Logging

Pipe tally annotations were missing top joint, and pipe tally report was missing bottom joint

All logging

Shooting impedence and differential impedence calculated from available outputs

OH Logging

Sane output value check added to Resistivities.

 

 

Release notes for Warrior Open-Cased 081008

All logging

New Titan Sand, Lime and Dolomite calculations.

OH Logging

Fix for line disable caused by relay changing for some tools

OH Logging

DLL (Dual Laterolog) minor enhancements

All logging

New Titan Neutron Algorithm.

All logging

Fix multiple pass automerge for time based logs

All logging

New Titan Neutron Algorithm; refinement over change done on Aug/25/2008.

OH Logging

Fixed bug where the calibration zero relay would stay set after user canceled the step.

All logging

Annotation edit dialog is resizeable.  Use File->Save Window Position option to save for next time.

All logging

Project measured depth given a TVD.  Can add a tie-on survey point with TVD, North, East, and then enter TVD survey points from there.

 

 

 

Release notes for Warrior Open-Cased 080730

TVD Calculations

Min curvature is now the default formula.  Old formula requires warrior.ini setting in [TVD] section: "Formula=Original" - Min curvature formula does not require warrior.ini setting

All Logging

Added CSS Slim CF252 Compensated Neutron Tool

All Logging

Corrected Ellipse area calculation formula, which is used for BH-Vol using XY Calipers

All Logging

Support for Robertson Geologging FWS and CBL tools with STIP

All Logging

Line Termination default set to High

All Logging

Added ability to opt for "comma-separated" values.

All Logging

Updated CNTP Titan algorithms

All Logging

Fix for extra long and multi page tiff files that are used for plot job input.

CH Logging

Tracer program crash at Recording stop bug fixed.

All Logging

Added user performable calibration sequence.

All Logging

Fix bug for calibration terms and support Lin1pt calibration with one sample point appropriatly

All Logging

ALT and DETEQ telemetry support directly from AUX channel with pulse discrimination

CH Logging

Enhancements for drawing highlight areas while perforating

All Logging

Add support for Printrex843, Sending less data to Printrex printers - using compression

CH Logging

Keep viewer in sync with interactive plot

All Logging

Bug fix depth on Y axis

CH Logging

Can disable items in XY plot, so this can be used as a quality indicator.  Show data points without showing calculations

CH Logging

Break pip tally annotations into two lines

All Logging

Enhance long/multi page tiff files

All Logging

Bug fix tape handling

All Logging

Bug fix tape handling

All Logging

Make units translation more accurate.  Bug fix tool import

CH Logging

More enhancements for perf job planner

OH Logging

Robertson Geologging SDEN now has the ability to calibrate the HRD sensor.

TCP

Fix for TCP drawing with broke tool lengths.

All logging

Window was preventing hardcopy dialog from being displayed

All logging

Fix error message from interactive plot at log stop when in Preview mode

 

 

Release notes for Warrior Open-Cased 071220

All Logging

Fixed bug that kept some logs from starting

 

 

Release notes for Warrior Open-Cased 071207

OH Logging

DLI Sidewall Neutron support

All logging

SGR frame time corrections and storage of cals in tools.ini

OH Logging

Multi-pt caliper calibration capability added.

All logging

Robertson SCNT slim-hole neutron model added.

OH Logging

Robertson SCDT slim-hole density model added.

OH Logging

ACE LSS tool support

OH Logging

ACE CBL tool support

All Logging

SDS CY driver updates to disconnect/reconnect gracefully

All Logging

LASW - Added default step size option to main dialog.  If you enter 0.5 for the default, then the next time the program starts, the Current sample rate will be set to 0.5

All Logging

LASW - Handle longer time logs

CH Logging

Multiarm.exe works better with new BHImg.dll.  Added bhimg presentation option to main dialog.  Must select a bhimg presentation for 3D Viewer to start.

All Logging

After total restore, run reinstall of drivers after reboot.

 

 

Release notes for Warrior Open-Cased 070814

Depth

In depth control, separate button added to connect to Depth Panel.  Apply button will only apply depth.

CH Logging

Hotwell PNN detection enhancements with auto thresholds

CH Logging

HDB3 (XIPE Caliper) and DAQING (Probe Caliper) telemetry enhancements

All logging

Fixed IMG PERR, MINR and MAXR curves

CH Logging

Sector based BIx and Attenuation curves, as well as an Image map.

All logging

External Power Supply Support

All logging

New CCL board support

All logging

CPFD and CPFH added

 

 

Release notes for Warrior Open-Cased 070628

All logging

User defined depth units reflected in naming of exported noise station wave files

CH Logging

Additional tool support for Spartek ILS and NFL

OH Logging

SP procesing optional through this tool module.

All logging

CanadaTech Pres. Support.

All logging

Added optional realtime output to usr tool module sensors

TVD Calculations

Add Minimum Curvature calculations.  Requires warrior.ini setting in [TVD] section: "Formula=MinCurvature"

 

 

Release notes for Warrior Open-Cased 070508

All Logging

Manual gain (range setting) option for noise service

TVD Calculations

Can read in curves from log pass for input to tvd calculations

PIP Logging

PIP panel PPAB Speaker output support

OH Logging

DLL bug fixes and some enhancements.

All Logging

Driver Firmware and Device Driver revision check for compatibility

CH Logging

Added Casing thickness curves to Image Plotting

PIP Logging

Bug fix for PIP Squelch

CH Logging

Fixed zero control bug on Applied Freepoint service

All Logging

Added Robertson Geologging Compensated Epithermal Neutron

OH Logging

Added Robertson Geologging Single Detector Density Tool

LIS Import

Fix for importing LIS data with multiple waveforms.

CH Logging

Added ability to batch export WAV sound files.

CH Logging

Daqing Caliper support, filter support for meas sensor

PIP Logging

Support FX1 based Pip panels

All Logging

Support Probe Shooting Panels with no AC shooting power capability

All Logging

Probe 2.75" CNT tool dolomite response updated

All Logging

Added check box to show/hide offsets of non-serial items in Tool Diagram

All Logging

Fixed gauge alarm settings not all translated to/from metric properly

OH Logging

SLT bug fix for frozen outputs after log stop

OH Logging

PSI caliper supporting reverse mode

LAS Export

Added option to output variables as curves in LAS export

All Logging

Lis2War uses standard Geodetic Units functions.

All Logging

Fixed USR tool calibration date bug.

All Logging

Support for Open Hole Shooting panel type

OH Logging

IEL Time drive non-advancement fixed.

All logging

Add UTCTIM, LOCTIM outputs.  Add to service same as TOD -> "LOCTIM=AUX,ELTIM".  LOCTIM is local time in seconds since 1/1/1970.  UTCTIM is seconds referenced to GMT.

Printing

Can print long jpegs.

Plotting

Add option to create black grid lines for a particular printer - overrides whatever grid lines were set to in log format. Some windows printers look better with black vs gray grid lines. 

Plotting

Multi line log inserts.  Signature spectrums can have colors.  More control over grid lines.

Plotting

Multi line log inserts.  Signature spectrums can have colors.

Plotting

Users have more control over how grid lines are created.

TVD plotting

New 3D closure plot.

Control Panel

Show version info in Control Panel.

 

 

Release notes for Warrior Open-Cased 061004

Plotting

Added filter report.  Fix plot jobs with multiple bitmaps.  More accurate plotter calibrations.

OH Logging

Fixed left-over bugs from the change to using percentage instead of raw DAC values.

All Logging

Optional Verifications for usr.dll tool software

All Logging

XIPE multi-arm caliper support

PL Logging

Made outputs available for time to depth logs

Logging with SDSTIP

Support solid-state aux power switching ("RelayPowerGate")

 

 

Release notes for Warrior Open-Cased 060818

Log formats

Add Image 3D and Potato plot types for multi arm caliper array data.

Plotting

Can start XYPlot when service starts like Iplot.  Extra parameters entered in Services Editor.

All logging

Generic Borehole Imaging tool module

All

Bugfix recalculation of depth-shifted data

CH Logging

Titan telemetry 24 bit raw data channel support

All Logging

Temp. Compensated XY Caliper tool; ported to Win-32.

Printing

Add calibration for Windows printers

CH Logging

Added spinner calculation program - Flowvelocity

All Logging

Added ability to write a time log to a DB; added a progress bar; reduced possibility of crash.

All logging

Compatibility fix for FX1 based hardware with VIA USB host controller

OH Logging

Ported DLL Tool from 16-bits to 32-bits.

All logging

Average Caliper output added to XYCal; slight clean-up.

Perforating

Use service dump for more accurate sensor offset calculations.  Bug fix - Closing all from Acquisition while wizard was open could delete joplan entries.

Tool string drawing

Use service dump for more accurate sensor offset calculations.

Alarms

Alarms now can be canceled in groups - depth, depthpnl using new alarms.

All logging

Multiple gain/filter board support, new I2C system addressing enhancements

All logging

Multiple DSP board support

All logging

New I2C system addressing enhancements, support for USB44R6

All logging

New I2C system addressing enhancements

TVD Calculations

Uses new tvd library - DS points will be saved in a database instead of external file.  TVD plots won't need to be saved to database, can be added to plot job later.

All logging

CNTP-313-B Probe Tool Added - New Algorithm.

OH Logging

MUX-E telemetry support

Headings

Headings can have watermarks

CH Logging

Panex Spinner Flow support

Tool string drawing

Version 2006.6.27.1 - User can create their own list of sensors to hide in the tool string drawing.  File logsys.ini, section [ToolDiagramSkipSensors], then list sensor names 1=SENS1, 2=SENS2, etc.

Plotting

Can enter a decimal value for line thickness to fine tune curve thickness on printers with resolution >= 300

Well Objects

Casing, plugs, packers can have colors.

All logging

New device for surface acquisition

All Logging

Bug fix for data transfer

Tool Power Monitor

Bugfix tool power monitor config, inhibit. Can now declare  “NoMonitor=yes” in specific services (or globally via Warrior.ini)

 

 

Release notes for Warrior Open-Cased 060407

CH Logging

Hotwell PNN downlink timing improvement and biased output returns to max. pos. rail for larger neg. deflections

All logging

Nominal gains and offsets for Tvolt and Tcurr by panel type

CH Logging

Sondex PL telemetry has new channel type "flowdir2" for modified XMW using two channels for flow rate and direction

CH Logging

Fix for PIP panel PLL multipliers

 

Release notes for Warrior Open-Cased 060327

All logging

Bug fix - Could cause "Unable to create curve" errors at log up time.

Windows printing

Can adjust resolution of Windows Printing source data via Warrior Control Panel.  Lower resolution speeds up printing but can lower print quality.  This setting is used in addition to the printer resolution set in the Windows printer settings.

XY Plot

Legend for curve names, Editable legend items, Uses banner for heading, Can plot constant values for reference.

Plotting

Add entry to warrior.ini in [Heading] section for "defaultbanner".  If entry not there then will use title.wlb

Sondex Support

Sondex PL supports flow detection on all lines including H2S. QPS bug fix

Plotting

Can show legend for shading in log inserts

All Logging

Prohibit Panel Type change (flag setting to enable in Warrior.ini)

All Logging

Logging releases use new style device drivers

All Logging

Sondex name fix, gauge overflow fix, smoother output filename handling

All Logging

Fix resource leak - was causing misc. device record and storage errors when recording multiple passes of logs with many outputs

Perforating

New Perf Job Planner

Sondex Support

Sondex MIT supported

Panex Support

Panex GR support, other updates per Panex

Cal reports

Cal reports now have a heading with database and dataset source for cals.

Printrex printing

For 820RM printers, add 820RM=1 to printrex printer section in warrior.ini.

Heading

Added 'U' for underline edit type in .hdg file.  "editHSLTU", "editVSLTU", etc.

Services Editor

Tools will be exported with service into wcf file by same name as wsv file.  Tools can be imported with service by same method.  When editing tools for service, can see list of current tool/serial numbers to pick from.

Panex Support

Bug fix to coefficients file read in

Panex Support

Enhanced Panex monitor and control

Creating Alias

Dialog will not close after alias created, but user will see status message if alias created successfully.

Backup

Was not checking set aside space for backups properly.

LIS export

Added option "OneFramePerRecord" to [LIS Export] section.  Required for WellCad software to read sonic data.

Cal reports

Can draw rectangles around entries by prepending underscore before text.  [Columns] entry can have start,stop values ( 1=0,20 ), and stop value for columns is required for rectangles to come out correct.

SCBL

Can manually adjust gates after automatic moves

Waveform Display

When multiple waveforms are in window, double click to fill window with that waveform and double click again to go back to multiple display.

Plotting to Fax

Move plot options to config dialog like other printers.  Add option for Normal ( 100dpi ) and Fine ( 200dpi ). Default is Fine - which is what it was hard coded to before.  Requires new entry in warrior.ini for [Fax] - "custom=faxfile32.dll".

Well Objects

Well object Highlight type can have different colors.  Perfs with single depth will show up now.

Plotting

Added 'repeat' mode for correlation curves.  Correlation curves will only be plotted if that curve is shown.  So you can show curves from main pass on top of repeat pass to easily see repeatability

All Logging

Default software power controls to be off, override via new control word in service or global enable via warrior.ini

All Logging

New safety feature: Tool Power will be disabled if line current drops out

Merge

Warn user if depth correction is entered and no curves have depth correction to be applied

Tracer Interp

Can use caliper reading as casing ID value for calculations

CH

Support for Geofizika PL string

Tool string drawing

Was not always showing proper offsets for tracer tools

All Logging

Open line monitor temporarily inhibited during tool power voltage/current calibration

Perforating

Update CYShpl support to monitor AC/DC and Pos/Neg switch positions when available

All logging

Modifactions to Sondex/CSS Compensated Neutron calibration and verification routines

Config restore

Run latest warrior convert option when restoring config files

Tool string drawing

Fix for multiple instances of the same tool

Direct printing

First plot from Job Editor will be spooled so printer won't start/stop

LAS Export

Fix CNTY=COUNTY

XY Plot

Can turn off curve labels.  Added more curve styles.  Print directly to Windows printer for better quality.

Hot var editor

Was not working properly on numeric values.

Waveform plotting

Fix for low vdl levels - before were coming out all white.

Interactive plot

Bug fix hangup of Iplot if you have it minimized and save a well object to the same database.

All logging

Big fix for probe telemetry channel offset and Titan "combined" channel types

Services,Tools editor

Saving a service will also create a file with tools for that service, then Import will look for both files

Format editor

Speed up reading/writing of log formats

All logging

CYAuxF1 - new device support

DSP logging

Ability to specify pmon for "Probe" command

All logging

Tool Power monitor settings can be specified per service

All logging

Robertson Geologging 6 Channel and 12 Channel Telemetry support

OH

Robertson Geologging Dual Induction in DILP tool support

All logging

CYShPnlF1 - new device support

CH Logging

Includes Hotwell PNN

CH Logging

Sondex PL telemetry has new channel type "flowdir2" for modified XMW using two channels for flow rate and direction

CH Logging

Hotwell PNN downlink timing improvement and biased output returns to max. pos. rail for larger neg. deflections

All logging

Nominal gains and offsets for Tvolt and Tcurr by panel type

 

 

 

Release notes for Warrior Open-Cased 051014

 

 

All logging

Warn if wireline is moving during service change

All logging

Add LSPDRT output

RS232 Output

Keyword DEPTHRT will output the realtime depth to the SERMON output stream

All logging

Bugfix certain problems when log is resized soon after start

All logging

Don’t close sensor monitor when device monitor opens

New tool

Pressure gradient tool, multiple types supported, variable or output curve inclination supported

CR2 telemetry

Tweaks to CR2 services

LAS Export

User can add their own heading information via [Heading] section in las.ini

All logging

Bug fix - Could causing "Unable to create curve" errors at log up time.

Windows printing

Can adjust resolution of Windows Printing source data via Warrior Control Panel.  Lower resolution speeds up printing but can lower print quality.  This setting is used in addition to the printer resolution set in the Windows printer settings.

All logging

Legend for curve names, Editable legend items, Uses banner for heading, Can plot constant values for reference.

Plotting

Add entry to warrior.ini in [Heading] section for "defaultbanner".  If entry not there then will use title.wlb

Sondex Support

Sondex PL supports flow detection on all lines including H2S. QPS bug fix

Plotting

Can show legend for shading in log inserts

All Logging

Prohibit Panel Type change (flag setting to enable in Warrior.ini)

All Logging

Logging releases use new style device drivers

All Logging

Sondex name fix, gauge overflow fix, smoother output filename handling

All Logging

Fix resource leak - was causing misc. device record and storage errors when recording multiple passes of logs with many outputs

Perforating

New Perf Job Planner

CTS Telemetry

CTS Telemetry monitor showing Caliper commands

Sondex Support

Sondex MIT supported

Panex Support

Panex GR support, other updates per Panex

Cal reports

Cal reports now have a heading with database and dataset source for cals.

Printrex printing

For 820RM printers, add 820RM=1 to printrex printer section in warrior.ini.

Heading

Added 'U' for underline edit type in .hdg file.  "editHSLTU", "editVSLTU", etc.

Services Editor

Tools will be exported with service into wcf file by same name as wsv file.  Tools can be imported with service by same method.  When editing tools for service, can see list of current tool/serial numbers to pick from.

Panex Support

Bug fix to coefficients file read in

Panex Support

Enhanced Panex monitor and control

Creating Alias

Dialog will not close after alias created, but user will see status message if alias created successfully.

Backup

Was not checking set aside space for backups properly.

LIS export

Added option "OneFramePerRecord" to [LIS Export] section.  Required for WellCad software to read sonic data.

Cal reports

Can draw rectangles around entries by prepending underscore before text.  [Columns] entry can have start,stop values ( 1=0,20 ), and stop value for columns is required for rectangles to come out correct.

Memory Logging

Major enhancements for LGAT,  Lonkar Gamma Analysis Tool

SCBL

Can manually adjust gates after automatic moves

Waveform Display

When multiple waveforms are in window, double click to fill window with that waveform and double click again to go back to multiple display.

Plotting to Fax

Move plot options to config dialog like other printers.  Add option for Normal ( 100dpi ) and Fine ( 200dpi ). Default is Fine - which is what it was hard coded to before.  Requires new entry in warrior.ini for [Fax] - "custom=faxfile32.dll".

Well Objects

Well object Highlight type can have different colors.  Perfs with single depth will show up now.

Plotting

Added 'repeat' mode for correlation curves.  Correlation curves will only be plotted if that curve is shown.  So you can show curves from main pass on top of repeat pass to easily see repeatability

All Logging

Default software power controls to be off, override via new control word in service or global enable via warrior.ini

All Logging

New safety feature: Tool Power will be disabled if line current drops out

Merge

Warn user if depth correction is entered and no curves have depth correction to be applied

Tracer Interp

Can use caliper reading as casing ID value for calculations

CH

Support for Geofizika PL string